Shanghai Chi Tang Electronics Co., Ltd. 主营:
咨询电话:13661497600
产品详情

GI-1 gel imaging system

  • 如果您对该产品感兴趣的话,可以
  • 产品名称:GI-1 gel imaging system
  • 产品型号:GI-1
  • 产品展商:Shanghai
  • 产品文档:无相关文档
简单介绍

GI-1 gel imaging system is simple and easy to use, real-time gel imaging system with high performance. Through the automatic control of GI-1 by gel-pro software, we can collect and analyze the protein

产品描述

GI-1Gel imaging system exercise do finger South

GI-1The upper part of the gel imaging system from top to bottom, aperture lens - Adjust the brightness of the image. Zoom - Adjust the size of the image. focusing - Adjust image clarity

GI-1The body of gel imaging system:

WL--- White light lamp switch.

300--- The UV light transmission switch, used for agarose gel electrophoresis.

254--- Ultraviolet reflective light source switch. For thin layer electrophoresis and dot blot hybridization.

365--- Ultraviolet reflective light source switch. For thin layer electrophoresis and dot blot hybridization.

White light conversion board:As with the white light transmission light source, the white board on the uviol open 300- The ultraviolet light source can be switched off. But for polypropylene amide electrophoresis

?

GI-1 Gel imaging system

?

Brief introduction

GI-1Gel imaging system is an easy-to-use, real-time Gel imaging high performance system. The gel-proSoftware pairGI-1The automatic control, we can on the protein gel, DNAGel: Set & Matchuff0c96Cell plate, plate samples for image acquisition and analysis.

?

Instrument performance

1.Using high resolution One 280 x 1024 Can capture images in real time CCD

2.The motor is automatically controlled F/1.2, C- Bayonet lens. In the instrument panel or the software to use the mouse to conveniently control the aperture (size Iris Zoom lens (zoom) Focus depth (focus) . C- Bayonet, F/1.2 Guaranteed big Incoming light and high imaging speed.

3.PC Machine control light source on and off

4.The sealed layer of special designed sealed darkroom can be upgraded to be used for collecting weak signals of Chemiluminescence

5.GI-1There are multiple light sources:Side white light, transmission ultraviolet , Transmitted white light (Bai Guangping). The side white light source is used for opaque sample such as photograph, paper hybrid, film and so on EB Dyeing DNA Gel: Set & Matchuff0c SYPRO Orange Fluorescence staining DNA , Radiant Red Fluorescence Dyeing RNA Gel; white light transmission is suitable for all kinds of Dyeing such as protein gel staining, silver staining. And Three Which kind of optional UV light is, to adapt to the user's special needs, they are to 254nm, 3 00nm, 365nm A center wide wavelength ultraviolet light source.

6.Maximum adhesive area: Two 5 x 20 cm, Gel suitable for all sizes.

7.Preparation type UV Lamp mode Prep UV ) and box drawer to facilitate the rubber cutting operation do

8.GI-1Be matched with1DSoftware and 2D Software Software pair, Software automatic control system, and provides a powerful function of qualitative, quantitative analysis. Chart, like sharing platform, user without password restrictions can be installed and used.

????

Radiant Red Dyeing RNA? SYPRO Orange Dyeing DNA EB Dyeing

The performance of finger standard:

CCD (Resolution H x V )

One Twenty-eight 0 x 1024

?

Pixel density

Eight (a Four thousand and ninety-six Gray scale)

Automatic zoom lens

C-mount, f/1.2,8 -48 Mm

Lighting mode

Transmission ultraviolet light, transmitted white light, upper white light

Excitation light source

Three 00 White light (standard), Two hundred and fifty-four , 365nm

Filter position

One

Chemiluminescence

Nothing

Transmission area

Two Five X 2 Zero CM

The compatibility of the do system.

Windows 2000/xp

Weight

Twenty Kg

?

Gel-pro analysis of Software

Software analysis function

It is a powerful and flexible Software package, chart like intake and analysis of one-dimensional gel electrophoresis, dot blot, slot blot and colony counting etc.. May carry on the analysis and cloning of StripAnalysisu3001 microplate gel. The results include: DNA/RNA Protein molecular weight and isoelectric point, migration differential, display, RFLP Analysisu3001 Fingerprinting Analysisu3001 autoradiographic film imaging, Ninety-six Quantitative Analysisu3001 orifice plate count and double counting cloning.

Stable image acquisition

The acquisition control window based? On application can automatically configure the filter, light source and other hardware configuration for the imaging system

Flexible lane and band analysis

Automatic detection of lanes and bands?

Rapid? Molecular weight determination, multiple regression models can be used to calculate the molecular weight using a variety of statistical regression calculation method.

Strip? / Matching analysis of lane, generate a tree

Rapid and simple quantification

The use of quantitative tools? Advanced, capable of carrying out accurate concentration analysis of rectangular, circular, or any nothing rules of the regional contour

Strip? For individual local background deduction function; automatically records the analysis function parameters, simplifies the analysis of Gauss model of precise and quantitative part of the sample overlapping spots

? the Software automatically, and the analysis of samples appear weak.

Automatic saturated pixel samples for? Accurate identification, quantitative analysis.

Image optimization and display

? under the control of Software to chart as do full angle image rotation chart , Adjust the brightness, contrast and image filtering and other processing.

By comparing images and pseudo? Color adjustment function, image quality was the most suitable.

Three dimensional observation mode can? Observe any user selected gel region to three-dimensional model

Image overlay and flip function?:

Superposition of multiple film observation function; film automatic turning function, users can set up turning speed; image acquisition mode, through the selection and observation of the sample screen, exposure time, get the best image.

?

Easy to use

Step by step guide? Function user friendly, application oriented menu interface follow analysis provided by Software analysis mode according to the wishes of the individual, easy to obtain analytical results.

Rapid application of fingersouth to guide you? From chart like collected data analysis and chart as data output, nothing Software.

Help to get the content? Directly on the screen

By clicking on the query? Icon suspended on the screen, you can get professional answers to the difficult questions at any time.

Suitable for? PC

TIFF? File input, TIFF And JPEG File output

Text annotations to the sample? Do markers.

Automatic Manager

? the powerful Automatic Manager can automatically save and run the following template function, nothing user intervention required:

Memory lane and the position? Of the sample

Determination of molecular weight?

Quantitative region labeling?

The text? And arrow mark

The advantages of andOther system:

Chart like clear, good stability, simple operation, use do Software friendly interface, convenient maintenance.

Hot tip: before using this instrument, please carefully read the instructions. The instructions shall and instrument together, in order to hold do at any time to read, once the instructions, please ask us for.

One, use:

Study on gel electrophoresis for chart as the set of laboratory equipment, using gel electrophoresis take digital camera is placed in the light tight box in the UV or white light image into the computer, through the corresponding gel analysis of Software, DNA, RNA, can complete the analysis of protein gel, TLC, etc. chart like, eventually from the peak of Strip molecular weight, gel or base pairs, area, height, position, or the total amount of sample volume.

Two, the structure characteristics of and

Gel imaging and analysis system is the analyzer with the black box, from ultraviolet transmission light, white light, black box, camera, computer system, Software gel analysis etc., in the bright room in do. The UV light with a white light source and three wavelength of the instrument, you can according to their own needs, using one wavelength light source alone, can also be used in several wavelength light source.

Product characteristics:

* High sensitivity, high resolution digital imaging system;

* White and ultraviolet light sources are provided, The silver staining, fluorescence, film, Coomassie brilliant blue, EBdyeingchart image digital processing;

* with gel analysis Software chart image analysis;

* Multipurpose box, from laboratory darkroom settings, and UV or white light transmission and UV reflection photography. At the same time taking into account the design to reduce the damage of UV on human as possible;

* The illumination is uniform and the maximum imaging area is reached200 * 250 mm.

Three, the main performance of finger standard

Basic parameters

Exterior sizeL * W * H): 440 x 430 x 770mm;

Wavelength of reflected ultraviolet light source:254nm, 365nm;

Wavelength of transmitted ultraviolet light source:300nm;

UV Transmission * 250mm area:200.

Environment condition:

Ambient temperature:5 to 40 DEG c;

Relative: humidity = 80%;

Atmospheric pressure:86kpa ~ 106kpa.

Power supply condition:

Supply voltage:Single phase sinusoidal communication220V 22V;

Frequency:50Hz + 1Hz.

Other:

The UV light irradiance window of each wavelength is not less than10 W/cm2;

Illumination of white light 100lx (Lux);

Continuous time 4Hour. do

Digital camera can realize connection through the and computer tomography imaging control, analysis of Software can achieve chart image edit processing, automatic lane recognition, molecular weight calculation, the sample volume distribution calculation.

Four, installation and use method

A and installation and dismantling:

1. packaging inspection instruments, if there are serious damage to promptly notify the dealer to resolve, nothing damage can be unboxed, should be carefully handled with unpacking process, to avoid damage to the instrument. Out of the box should have instrument control list to check all the items, please contact the dealer, and.

2. In the instrument power supply socket missed under the condition of power switch box, panel are placed in the off state (On the power switch To get through. "I" is "Disconnect". The transmission box on) the tray; as with white light, directly converting plate on the transmission box.

Notice: excessive ultraviolet radiation will cause harm to the human body, so the UV light must be do in the dark box, the use of prohibited exposure!

3. After the digital camera and lens are screwed, the near mirror, filter and transfer ring are all screwed on the lens, and then the digital camera is fixed on the bracket of the top of the black box, and the knob is screwed and connected to the controller power supply Camera lensUSBand computer Connect line with the USB line of the digital camera and Connect computer.

B, Software installation

1).Installing digital cameras

ConnectCCDand computer, the following screen appears.

Chart4

?

Chart5

Chart6

?

Chart7

?

?

Chart8

2). Analysis of Software installation

1.double-clickSETUP-START-OK

Chart11

?

Two Take WINDOWS Copy folder to C:/ Cover the root in the root directory WINDOWS

?

CShooting

?

Openscan to new documentThe following dialog box appears.Ver.offset Numerical exposure time0-2000. Arbitrary adjustment. Cap.framesby1. Like to scan documents into chart. Quit shooting program. Take exit procedures at the same time each open will automatically shut down

?

?

Chart14

?

D, chart image analysis

Please refer to the chart image analysis GEL-PRO analysis Software.

Five, matters needing attention:

1. after receiving the user please as soon as possible out of the box inspection, if not normal circumstances, please delivery within one week after the and contact our factory, in order to solve.

2.We should prevent the collision and vibration during transportation, so as to avoid UV glass and UV lamp damage. Should be stored in the humidity of no more than93%, ambient temperature0 to 55 DEG C, nothing corrosive gas and clean indoor ventilation.

3.The instrument used in all metal structure, should be used to ensure the socket grounding.

4. UV light after the power is switched on the lights, the UV light must be do in the dark box, the use of prohibited exposure.

Notice:a. excessive ultraviolet radiation will cause harm to the human body, so the UV light must be do in the dark box, the use of prohibited exposure!

B.Add or replace the transmission box before, must first cut off the power supply!

5. use of such as the discovery of other anomalies should be immediately shut down, to repair. If there is a faulty instrument, please contact our factory and repair.

The generated brightness decay, aging is inevitable 6. UV Lamp in in normal use, according to the use of frequency, Lamp in3 to 12 months to replace the normal, this does not belong to the scope of warranty. Other fault free warranty for one year, after the failure, I plant is still responsible for the maintenance, reasonable fees.

If you have any questions please contact our factory technical service center and.

Six.Routine maintenance methods:

1. the instrument should be placed in a cool, dry, nothing dust and nothing acid, steam, instrument use environment should be clean. Long time no should unplug the power plug and cover protective cover.

2. don't take water and liquid splash instrument.

3. The light box is placed on the observation by the glass as filth, rubbing alcohol clean available.

Seven.Service commitment to users:

This product uses the term by4Year. The product is guaranteed for one year after sale:Within a year Non improper use, is a product quality problems, responsible for repair, material costs, repair fees, return freight, all free. More than one year, responsible for maintenance. Reasonable collection of material fees, repair fees.

????

Eight.Transportation and storage

Transport: the transport analyzer according to the provisions of the contract execution.

Keep in storage:After packing, the product should be stored in the product0 to +55 DEG C, relative humidity, nothing is not greater than 93% corrosive gas, good ventilation indoors.

产品留言
标题
联系人
联系电话
内容
验证码
点击换一张
注:1.可以使用快捷键Alt+S或Ctrl+Enter发送信息!
2.如有必要,请您留下您的详细联系方式!
Copyright@ 2003-2025  Shanghai Chi Tang Electronics Co., Ltd.版权所有      电话:13661497600 传真: 地址: 邮编: