Application of UV-2000 type high intensity UV analyzer:?
This factory uses the ultraviolet lamp tube, filter and filter after * * precision processing, the quality of the domestic best, therefore, the UV output strong, uniform, can make the film sample time is greatly shortened, the film is clear and no stray light background.
UV-2000 type high intensity UV analysis is a new analytical instrument is developed successfully.
This product has the advantages of high sensitivity, convenient use, especially with the wavelength of 302NM damage to the sample is smaller, replacement of ultraviolet analyzer updates, UV-2000 type high intensity UV analyzer with a fully enclosed high-quality metal box, no need to operate in a dark room, convenient use, simple operation, the equipment can be installed for digital camera. Filming and taking pictures for DNA, RNA gel, protein gel; thin-layer chromatography, analytical instrument is indispensable study of molecular biology identification of teaching and scientific research units.
The instrument is equipped with a set of transmission of ultraviolet light for observation, analysis and photography. And a specially designed box, the user does not require darkroom, you can observe and analyze the samples, the black box is equipped with a dedicated camera installation device, camera obscura observation room is equipped with anti UV glass, more than 95% of its least squares ultraviolet. The instrument design of tapping on both sides of the box and observation window window speaking population, facilitate the division of nucleic acid samples. Ultraviolet transmission 302nm; a group of incandescent lamp
The characteristics of UV-2000 type high intensity UV analyzer products:?
Four back-up light source apparatus of 302nm, 254nm, 365nm and white L?
The instrument design of tapping on both sides of the box and observation window, convenient for cutting l gel samples?
The full closure of high-quality ABS plastic box integration, without operating in a dark room?
Open the drawer box, can automatically turn off the light from UV damage L?
Ultraviolet fluorescence conversion board, directly on the fluorescent film to ultraviolet light, easy to switch between UV and visible light, suitable for different experimental requirements?
The instrument is equipped with a digital camera, a fixed port L?
The built-in reflector device, the ultraviolet light more evenly, improves the detection sensitivity?
UV filter with special processing, clear background, no shadow lamp L?
Technical indicators
Product Name
|
UV-3000 high intensity UV analyzer
|
UV-2000 high intensity UV analyzer
|
Rail type UV transmission station
|
* * filter area 200 x 200mm
|
The UV light source
|
302nm
|
Bilateral UV reflection
|
254nm 365nm
|
?
|
UV lamp
|
15W * 12
|
15W * 8
|
* * reflection filter
|
200 x 50mm
|
?
|
Both sides of the white light
|
visible light 4W * 2
|
White board area
|
210 x 260mm
|
camera (optional)
|
Digital SLR camera? 10 million 750 thousand pixels, 3 inch display
|
Fluorescence camera lens (optional)
|
With a camera shooting fluorescent mirror, camera interface
|
Defects Liability Period
|
A year
|
weight
|
12KG
|
Power Supply
|
AC220V + 10% 50HZ
|
Matching
|
Inkjet printer, print independent inserted Kaka, editor of shear print experiment data images directly
|
An instrument:
High intensity UV analyzer
|
UV lamp
|
uv filter
|
Equipped with hot AC ballast insurance
|
Ultraviolet camera
|
Special digital camera
|
UV-2000 type high intensity UV analyzer for use?
(a), observation and analysis of samples
1, connect the power line?
If the gel is observed, suggested the use of wavelength 302nm, wavelength selective switch 302nm please press to open at this time, to observe the strength to prepare for the preparation of the gel samples, observation and cutting operation, to reduce UV damage to DNA, please 365nm or 254nm to open the switch wavelength. The suitable wavelength selection, you can observe and analyze the gel and cutting operation.
The gel samples or thin paper layer, 2. samples will be good electrophoresis on the instrument the central, open source, so that the sample sent the clearest bright fluorescence. UV reflection from the sample is usually closer, then the more intense fluorescence. Starting about three minutes is the best time to observe and take pictures, not to be missed.?
3. if the rubber cutting section, stretching his hands on both sides of the mouth can be.
4. fluorescent UV conversion board, directly to the fluorescent plate on the UV light, can realize switching between UV and visible light, suitable for protein gel analysis.
(two), photo shoot
1, install the camera stand and the fixing screw. The camera can be as long as the installation of filters
2, the camera into the camera seat in the middle hole, when the camera to take pictures after the stable. Note: adjust the camera lens should be prepared in advance, to take timely. In order to shoot the best stable shutter cable or device.
(note three):?
1 should turn off the UV lamp switch is placed in front of the film, to prevent ultraviolet leakage body burns.?
The protective film to UV filter on tear off before using.?
We should turn off the power switch in the observation, to extend the life of the ultraviolet lamp.?
It is prohibited to use metal and other hard materials in direct contact with the UV filter, so as not to scratch the UV filter.?
The prevention of pollution of electrophoretic liquid UV filter.?
And if there is condition, please clean regularly with anhydrous ethanol UV filter to prevent mildew, UV filter