The humanized design
The drawing of stainless steel, four angle semi circle arc transition, shelf free handling, easy to clean studio.
The water jacket heating mode, ensure the studio temperature uniformity in the off state, can keep constant temperature for longer.
The box is easy to observe the glass door in the working state, the user can open the glass door at any time, the incubator will automatically stop working, and cut off the heating and circulating fan.
The microcomputer controller; self-tuning PID Technology will not form the temperature overshoot; with temperature, water level and open alarm humanization design function, can avoid sudden temperature damage on experimental samples.
The automatic control of circulating fan speed
The circulating fan velocity can be controlled automatically, when the temperature is constant, the speed will decrease, circulation velocity will adjust to wind speed for cell growth, avoid excessive volume due to the volatilization of the sample during the test.
The LCD multi segment programmable controller (optional)
The multi segment LCD programmable controller, various parameters of a screen display, menu operation interface, can simplify the complex test process, realize the automatic control and operation.
The parameters of multi section temperature, wind speed, cycle time and heating rate can be set at the same time and programming, can control the upward temperature gradient, from the initial temperature of slow heating box, can be preset automatic startup, standby and shutdown function.
Can be preset Seven paragraph Sixty-three Each step can be programmed Nine Every step, setting time One ~ Ninety-nine hour Fifty-nine Branch.
The safety function
- independent limit temperature alarm system, alarm prompts the operator to ensure the safe operation of the experiment, no accident.
Having low temperature, high and ultra mild water alarm.
Having a long time to open the door alarm.
The UV sterilization system (optional)
Can be disinfected regularly to the inside of the box, which can effectively kill the bacteria floating box in the circulating air, thereby effectively preventing pollution during the cell culture
?
?
Model
Technical indicators
|
GHP-9050 GHP-9050N
|
GHP-9080 GHP-9080N
|
GHP-9160 GHP-9160N
|
GHP-9270 GHP-9270N
|
supply voltage
|
AC220V 50HZ
|
Heating mode
|
Water jacket
|
temperature range
|
RT+5 ~ Sixty-five C
|
Temperature resolution / Volatility
|
Zero point one C / . Zero point three C
|
Temperature uniformity
|
. Zero point five C ( Test point Thirty-seven C )
|
Working environment temperature
|
+5 ~ Thirty-five C
|
Input power
|
450W
|
650W
|
850W
|
1350W
|
volume
|
50L
|
80L
|
160L
|
270L
|
Tank size (mm) W * D * H
|
Three hundred and fifty * Three hundred and fifty * Four hundred and ten
|
Four hundred * Four hundred * Five hundred
|
Five hundred * Five hundred * Six hundred and fifty
|
Six hundred * Six hundred * Seven hundred and fifty
|
Size (mm) W * D * H
|
Five hundred * Five hundred * Seven hundred
|
Five hundred and fifty * Five hundred and fifty * Eight hundred
|
Six hundred and fifty * Six hundred and forty * Nine hundred and fifty
|
Seven hundred and fifty * Seven hundred and forty * One thousand and fifty
|
Carrying bracket (standard)
|
Two block
|
Timing range
|
One ~ 5999min
|
Price
|
RMB4590 RMB5390
|
RMB5290 RMB6090
|
RMB7390 RMB8190
|
RMB9590 RMB11390
|