Atomic absorption spectrophotometer

  • 如果您对该产品感兴趣的话,可以
  • 产品名称:Atomic absorption spectrophotometer
  • 产品型号:361CRT
  • 产品展商:Shanghai instrument electricity
  • 产品文档:无相关文档
简单介绍

This series of atomic absorption spectrophotometer is the popularity of a new generation of intelligent instruments. Its performance is very stable, powerful data processing can make the operation ins

产品描述


Type no.

361MC

361CRT

The class type

Fire type (air - acetylene), intelligent

The optical system

Single beam, C - T monochromator, grating of 1200 lines/mm, blaze wavelength of 250 nm, spectrumbandwidth
0 ~ 2 nm, the relative aperture of F / 5.4

The light source system

Two sets of the lamp power supply independent power supply, pulse light, lamp power supply 0 ~ 30 ma

Computer specifications

8031 single chip microcomputer CPU, EPROM 16 KB RAM 8 KB

General personal computer (excellent name-brand computer, multimedia configuration)

Reading form

Four LED display, direct reading T, A, C, RSD, print data and reports, working curve drawing, data recorder (2 v, 1 v)

Screen reading: five floating point, direct reading T, A, C, RSD, display the work curve, analysis report, instantaneous record curve (paperless recorder function)

Way to work

Transmittance, atomic absorption method, flame emission method, hollow cathode deuterium lamp secondary background subtraction

Signal form

Continuous reading (instantaneous value), the average reading (keep), peak height and peak area

Concentration calculation

Linear regression and curve fitting, the standard addition method

The number of the prototype

1 ~ 6

1 ~ 8

Reading preparation time

0 ~ 100 seconds for 0.1 seconds

0 ~ 100 seconds

Integral sampling time

Same as above

0.1 to 20 seconds

Scale extension

1 ~ 20 times interval

1 ~ 20 times

Repeat an average

1 ~ 100 times to get an average

1 ~ 20 times

Results the storage

There is no

There are

Other features

Automatically, automatic sensitivity and baseline drift correction, automatic calculation of relative standard deviation, automatic printing analysis data, working curve, the instrument parameter list, analysis report, CRT type can store more than content in the machine, with a Chinese version of the experts and query system, including the best conditions of setting, sample preparation and the interference of hint, can provide eight work curve in order to compare and to modify the standard point.

Gas control

Air pressure acetylene flow direction, the secondary explosion protection, voltage regulator valve regulated multistage imports

Main engine size and weight

800mm×540mm×420mm 50㎏

Model/options

361MC

361CRT

The printer

Pp40 four-color printing drawing machine

EPSON inkjet printer or 1600 k needle
compatibles

recorder

Type 3066-11 (assembly yokohama, Japan) don't have to (take the paperless record instrument)

The hollow cathode lamp

Specifications complete, according to the device under test can be take into consideration the choose and buy


Main features:
Low feature-rich: computer automatically deduct blank value, deducted automatically sensitivity drift, deducted automatically baseline drift, automatic computing mean value and deviation, the working curve equation is calculated and read density automatically, automatic printing analysis report, still can undertake flame emission spectrophotometry, hydride generation atomic absorption analysis and flow injection on-line enrichment atomic absorption method.After two sensitivity to graphite furnace level, but the price is far lower than the graphite furnace.
When the operation is simple: every time after the condition set, only keys 2, can automatically read/print out the absorbance value, density and relative standard deviation.Compared with no microcomputer instrument, saved a lot of manual data processing time.
Low signal stability: USES the import high quality photomultiplier and advanced integrated circuit, the single beam optical path, light monochromator and the effective atomizer, low noise, good accuracy.Computer accurate logarithmic transformation, no temperature drift, baseline stability is good.
Low expert system: the novice teacher and consultant (only361CRTType).
Low resistance to corrosion of atomization system: atomizing chamber adopts high quality engineering plastic, burner with long life, fast heat balance type titanium burner, can achieve a long time without water cooling but determination sensitivity is not change.
Low efficient atomizer, high sensitivity and high reproducibility.
For low peak fine: special wavelength can fine tuning mechanism on the wavelength peak position accurately.
Low continuous slit: original with high resolution and continuous slit mechanism to ensure the best spectral bandwidth.
Low rust prevention performance is good, pure quality engineering plastic atomizing chamber completely solve the rust and water problem.
Good low security: equipped with secondary explosion-proof measures, even if air break, also won't accidents.
When complete: random complete, can use after purchase.A variety of form a complete set of combination of choose and buy, greatly expands the application range of this machine.

Technical indicators:
Low wavelength range:190nm~900nm
Low wavelength error value:≤±0.5nm
Low wavelength repeatability: better than0.3nm(one-way)
Low resolution: distinguish manganese double wave valley< 40% (0.2 nm spectral bandwidth
Low baseline stability: better than0.004A/30min(Copper)
Low detection limit.< 0.007 mu g/ml (copper)
The characteristics of low concentration: < 0.04 mu g/ml / 1% (copper)

Other:
Low working power supply:220V±22V/50Hz 110V±11V/60Hz