Multi parameter water quality analyzer

  • 如果您对该产品感兴趣的话,可以
  • 产品名称:Multi parameter water quality analyzer
  • 产品型号:Bante900
  • 产品展商:Shanghai special
  • 产品文档:无相关文档
简单介绍

High precision multi parameter water quality analyzer, built the system menu, the 15 functions of optional parameters, the instrument is suitable for the measurement of liquid pH, redox potential, ion

产品描述

The pH model features:
- high precision multi parameter water quality analyzer, equipped with a large screen backlit LCD display.
1 - to 5 bit keys calibration, automatic recognition of pH standard buffer solution.
- optional pH buffer (USA/NIST/DIN) or 2 custom calibration.
- automatic electrode slope, suggesting that the current status of sensor.
The ORP model features:
1 - point offset calibration, allowing adjustment of the display value to a known standard.
- relative or absolute mV measurement mode to provide accurate readings ORP.
 Laboratory pH meter.Jpg
Ion mode features:
2 - to 5 points up to 8 keys calibration, optional ion concentration calibration point.
- automatic identification of ion selective electrode, without specifying the type of ion.
Measurement of direct reading concentration - value, avoid cumbersome conversion and calculation.
- optional concentration units (ppm, mg/L, mol/L), to meet the diverse needs of ion measurement.
The conductivity / resistivity model features /TDS/ salinity:
1 - to 5 bit keys calibration, automatic identification of conductance standard solution.
- optional electrode constant (K=0.1/1/10), suitable for different types of electrodes with conductance.
- optional TDS conversion factor, standard temperature (20 or 25 DEG C), salinity (seawater salinity measurement mode or utility), with different water quality
Measurement requirements.
- linear and water temperature compensation mode, ensure the accuracy of measurement.
The dissolved oxygen model features:
1 - or 2 bit keys calibration, providing full range of linear measurement.
- Manual salinity and atmospheric pressure compensation, improve the measuring accuracy.
 Laboratory pH meter.Jpg
General characteristics:
The automatic temperature compensation, to ensure the high precision throughout the entire range.
The automatic calibration reminder prompts the user calibration instrument.
- stable data icon to display the current status of measurement.
Lock - Automatic end point measurement, keep a stable value for easy browsing or recording.
- manual temperature calibration, improve measure precision of temperature.
- optional units of temperature (~ C or ~ F), meet different national habits.
- automatic electrode diagnosis, consult the electrode zero offset, the slope value, or poor conductivity K value.
Help message, as a simplified instrument application real-time operation guide.
- the system menu allows the user to customize the calibration point, stability criteria, data lock mode, automatic shutdown function parameter 15.
- one key reset (Reset) automatic recovery instrument to the factory default settings.
- extended memory can store up to 500 sets of measurements.
- built-in clock automatic marking data storage date, time to comply with the GLP specification.
USB communication interface to send data to a personal computer storage.

Model

Bante900

PH

measuring range

-2.000~20.000pH

measurement accuracy

+ 0.002pH

Display resolution

Zero point one 0.01, 0.001pH.

Calibration point

One To 5 points

The use of calibration solution

USA, NIST, DIN

Temperature compensation range

0~100 ~ C, 32~212 ~ F

Temperature compensation

Manual or automatic

MV

measuring range

-1999.9~1999.9mV

measurement accuracy

+ 0.2mV

Display resolution

Zero point one 1mV.

Calibration point

One Point (only for R.mV)

The calibration range

+ 200mV

Ion

measuring range

0.001~19999ppm, mg/L, mol/L ( Please refer to the actual measuring ion electrode description)

measurement accuracy

0.5% F.S (a +), F.S (two + 1% +)

Display resolution

Zero point zero zero one 0.01, 0.1, 1.

Calibration point

Two To 5 points

The use of calibration solution

0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000 (ppm, mol/L, mg/L)

Temperature compensation range

0~100 ~ C, 32~212 ~ F

Temperature compensation

Manual or automatic

conductivity

measuring range

0~20.00 200.02000, S/cm, 20.00200.0mS/cm

measurement accuracy

+ 0.5% F.S

Display resolution

Zero point zero one 0.1, 1.

Calibration point

One To 5 points

The use of calibration solution

10 S/cm , 84 S/cm, 1413 S/cm, 12.88mS/cm, 111.8mS/cm

Temperature compensation range

0~100 ~ C 32~212, F

Temperature compensation

Manual or automatic

Temperature compensation coefficient

0.0~10.0%/ ~ C

Temperature compensation mode

Linear or pure water

Conductivity cell constant

K=0.1 1, 10.

Standard temperature

Twenty C Or 25 degrees C

TDS

measuring range

(0~10ppt The maximum 20ppt, by setting the TDS conversion factor)

measurement accuracy

+ 1% F.S

Conversion factor

(0.1~1.0 The default is 0.5)

salinity

measuring range

(0~10ppt The maximum 80ppt)

measurement accuracy

+ 1% F.S

Measurement mode

Practical salinity (PSU) and salinity (PPT)

resistivity

measuring range

0~100M.

measurement accuracy

+ 1% F.S

Display resolution

Zero point zero one 0.1, 1.

The concentration of dissolved oxygen

measuring range

(0.00~20.00mg/L Or PPM)

measurement accuracy

+ 0.2mg/L

Display resolution

0.01mg/L

Temperature compensation range

0~50 ~ C 32~122, F

Temperature compensation

automatic

Atmospheric pressure compensation

60.0~112.5kPa 450~850mmHg.

Salinity compensation range

0~50g/L

% saturation

measuring range

0.0~200.0%

measurement accuracy

+ 2%

Display resolution

0.1%

temperature

measuring range

0~105 ~ C, 32~221 ~ F

measurement accuracy

+ 0.5 ~ C, 0.9 ~ F.

Display resolution

0.1 ~ C

The calibration range

The measurement value of + 10 ~ C

Temperature unit

C Or F, optional

Other

Data lock

Lock the manual or automatic end point

The stability condition of data

Fast and high precision

Calibration reminder

One To 31 days on or off

Off Mode

Manual or automatic (no key operation after 10, 20, 30 minutes)

One key reset function

Contain

Data storage

Five hundred group

Communication output

USB

Connector

BNC 6 pin, MINI

The type of power supply

The DC5V power adapter

Shell material

ABS

Size

(210 Long) * 188 (wide) x 60 (high) mm

Instrument weight

1.5kg