Model
|
|
Bante900
|
PH
|
measuring range
|
|
-2.000~20.000pH
|
measurement accuracy
|
|
+ 0.002pH
|
Display resolution
|
|
Zero point one 0.01, 0.001pH.
|
Calibration point
|
|
One To 5 points
|
The use of calibration solution
|
|
USA, NIST, DIN
|
Temperature compensation range
|
|
0~100 ~ C, 32~212 ~ F
|
Temperature compensation
|
|
Manual or automatic
|
MV
|
measuring range
|
|
-1999.9~1999.9mV
|
measurement accuracy
|
|
+ 0.2mV
|
Display resolution
|
|
Zero point one 1mV.
|
Calibration point
|
|
One Point (only for R.mV)
|
The calibration range
|
|
+ 200mV
|
Ion
|
measuring range
|
|
0.001~19999ppm, mg/L, mol/L ( Please refer to the actual measuring ion electrode description)
|
measurement accuracy
|
|
0.5% F.S (a +), F.S (two + 1% +)
|
Display resolution
|
|
Zero point zero zero one 0.01, 0.1, 1.
|
Calibration point
|
|
Two To 5 points
|
The use of calibration solution
|
|
0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000 (ppm, mol/L, mg/L)
|
Temperature compensation range
|
|
0~100 ~ C, 32~212 ~ F
|
Temperature compensation
|
|
Manual or automatic
|
conductivity
|
measuring range
|
|
0~20.00 200.02000, S/cm, 20.00200.0mS/cm
|
measurement accuracy
|
|
+ 0.5% F.S
|
Display resolution
|
|
Zero point zero one 0.1, 1.
|
Calibration point
|
|
One To 5 points
|
The use of calibration solution
|
|
10 S/cm , 84 S/cm, 1413 S/cm, 12.88mS/cm, 111.8mS/cm
|
Temperature compensation range
|
|
0~100 ~ C 32~212, F
|
Temperature compensation
|
|
Manual or automatic
|
Temperature compensation coefficient
|
|
0.0~10.0%/ ~ C
|
Temperature compensation mode
|
|
Linear or pure water
|
Conductivity cell constant
|
|
K=0.1 1, 10.
|
Standard temperature
|
|
Twenty C Or 25 degrees C
|
TDS
|
measuring range
|
|
(0~10ppt The maximum 20ppt, by setting the TDS conversion factor)
|
measurement accuracy
|
|
+ 1% F.S
|
Conversion factor
|
|
(0.1~1.0 The default is 0.5)
|
salinity
|
measuring range
|
|
(0~10ppt The maximum 80ppt)
|
measurement accuracy
|
|
+ 1% F.S
|
Measurement mode
|
|
Practical salinity (PSU) and salinity (PPT)
|
resistivity
|
measuring range
|
|
0~100M.
|
measurement accuracy
|
|
+ 1% F.S
|
Display resolution
|
|
Zero point zero one 0.1, 1.
|
The concentration of dissolved oxygen
|
measuring range
|
|
(0.00~20.00mg/L Or PPM)
|
measurement accuracy
|
|
+ 0.2mg/L
|
Display resolution
|
|
0.01mg/L
|
Temperature compensation range
|
|
0~50 ~ C 32~122, F
|
Temperature compensation
|
|
automatic
|
Atmospheric pressure compensation
|
|
60.0~112.5kPa 450~850mmHg.
|
Salinity compensation range
|
|
0~50g/L
|
% saturation
|
measuring range
|
|
0.0~200.0%
|
measurement accuracy
|
|
+ 2%
|
Display resolution
|
|
0.1%
|
temperature
|
measuring range
|
|
0~105 ~ C, 32~221 ~ F
|
measurement accuracy
|
|
+ 0.5 ~ C, 0.9 ~ F.
|
Display resolution
|
|
0.1 ~ C
|
The calibration range
|
|
The measurement value of + 10 ~ C
|
Temperature unit
|
|
C Or F, optional
|
Other
|
Data lock
|
|
Lock the manual or automatic end point
|
The stability condition of data
|
|
Fast and high precision
|
Calibration reminder
|
|
One To 31 days on or off
|
Off Mode
|
|
Manual or automatic (no key operation after 10, 20, 30 minutes)
|
One key reset function
|
|
Contain
|
Data storage
|
|
Five hundred group
|
Communication output
|
|
USB
|
Connector
|
|
BNC 6 pin, MINI
|
The type of power supply
|
|
The DC5V power adapter
|
Shell material
|
|
ABS
|
Size
|
|
(210 Long) * 188 (wide) x 60 (high) mm
|
Instrument weight
|
|
1.5kg
|