A, use
?????? Digital universal tool microscope 19JC And by grating and digital technology, has the characteristics of visual reading and good consistency, improve work efficiency, to further expand the scope of use.
?????? A digital watch strap instrument data output interface, can connect 2D data acquisition processor and computer operating system upgrade for the measurement. 19JPC Computer type universal tool microscope system.
????? The instrument can be used imaging method, the axial and tangential method or contact method for precision measurement in Cartesian or polar coordinates of machine tools and parts of the length, angle and shape position relationship, and equipped with a full set of accessories, the use of fully expanded range.
?
Two, technical parameters
One The measurement range and the index value.
X - Y coordinate???? ? Measuring range: X? -? Y To: Two hundred? *? One hundred? millimeter
???????????????? ?????? Division value:?????????????? Digital display:?????? Zero Point Zero Zero Zero Five millimeter
??? Targeting microscope????? Lift travel:???????????? One hundred and twenty millimeter
???????????????? ?????? Vertical tilt range:???????? All around Fifteen degree?????? Division value: Ten branch
??????????????????? ??? Lighting aperture adjustment range:???? Phi Three ~ Phi Thirty-two millimeter????? Division value: One millimeter
??? Goniometer eyepiece?????? ? Angle measuring range: Three hundred and sixty degree??????????? Division value: One branch
??? Eye contour?????? ? Angle measuring range:???????? .? Seven degree?????????? Division value: Ten branch
???????????????? ?????? Arc reticle:?????????? Radius of curvature: R 0.1 ~ One hundred millimeter
???????????????? ?????? Thread reticle:?????????? The common thread: T = 0.25? Six millimeter
??????????????????????????????????????? Trapezoidal thread: T = 2? Twenty millimeter
??? Optical dividing table???? Measuring range: Three hundred and sixty degree??????????? Division value: Ten Seconds (projection reading)
??
?? (optional)???? Glass table diameter:??????? ? Phi One hundred and six millimeter
??? Optical dividing head???? Measuring range: Three hundred and sixty degree??????????? Division value: One branch
??? Optical locator???? Measuring head diameter:????????????? ? Phi Three? .? Zero point one Mm (limit error value is less than the actual diameter Zero point five M)
???????????????? ????? Measuring force: 8 -? Fourteen gram
???????????????? ????? Maximum depth measurement: Fifteen millimeter
??? Glass table???? Glass table size: Two hundred and fifteen * One hundred and thirty millimeter
??? Thimble rack???????? ? Maximum clamping diameter:?????????? Phi One hundred millimeter
???????????????? ??? Maximum clamping length:?????? The measured diameter is less than or equal to Fifty-five Mm: Seven hundred and fifty millimeter
?????????????????????????????????????? ?????????????? The measured diameter. Fifty-five Mm: Six hundred millimeter
??? High frame thimble????? ? Maximum clamping diameter:?????????? Phi One hundred and eighty millimeter
???????????????? ????? Maximum clamping length: Six hundred millimeter
V Frame??????? ? Left V Before and after the frame before and after the adjustment range: Five millimeter
???????????????? ???? right V Frame height adjustment range: up Fifteen Mm; down Three millimeter
??? Maximum load Forty Kg.
Two Aiming at the optical parameters of microscope
Magnification of objective
|
One *
|
Five *
|
Five *
|
Total magnification
|
With the angular or profile eyepiece
|
Ten *
|
Thirty *
|
Fifty *
|
Double image eyepiece
|
Fifteen *
|
Forty-two *
|
Sixty-five *
|
Field of view ( millimeter )
|
With the angular or profile eyepiece
|
Good Twenty
|
Good Six point six
|
Good Four
|
Double image eyepiece
|
Good Thirteen
|
Good Four point seven
|
Good Three
|
Working distance ( millimeter )
|
With the angular or profile eyepiece
|
Eighty-one
|
Ninety
|
Sixty-five
|
Double image eyepiece
|
Forty-seven
|
Eighty-five
|
Sixty-three
|
?
Three The precision of the instrument.
??? Temperature requirements?????? The studio temperature should be Twenty? .? Two? C
????????????????? The studio temperature change per hour does not exceed One? C
????????????????? The measured instrument and the temperature difference is not more than? Zero point five? C
??? To meet the specified temperature conditions, instrument has the following guarantee:?
??? 1.? X - Y coordinate?? Glass mm divided scale was verified, the maximum allowed instrument accuracy:
Zero (grade: 1 / 100 + L Mu) M Type = L? Length measuring unit: mm
??? The goniometer eyepiece??? Maximum allowed angle measuring accuracy: not more than One branch
??? The double image eyepiece??? Like instability:???????? Not more than Zero Point Zero Zero Zero Five millimeter
????????????????? Like the incorrect degree:???????? Not more than Zero point zero zero one millimeter
??? The optical sub-heads'greatest inaccuracy:?????????? Not more than One branch
??? The maximum allowed the accuracy of optical dividing table:?????????? Not more than Thirty Seconds (optional)
??? The optical localizer to measure the instability:???????? Not more than Zero point zero zero one millimeter
????????????????? Uncertainty of measurement:???????? Not more than Zero point zero zero one five millimeter
Four? The weight of the instrument?????? Host weight:?????????????? about Two hundred and fifty Kg.
Size X? *? Y? *? Z? : Nine hundred and eighty? *? One thousand and twenty? *? Six hundred and forty? millimeter
?
Three, complete system
One Host : 19JC Digital universal tool microscope
Two The two-dimensional data acquisition processor
Three Two dimensional measurement computer operating system ( Software A)
Four Microscopic imaging system :?
(1) The main microscope Y To arm
(2) Camera lens : 3 * Five *
(3) Video adapter
(4) Image sensor camera
Five image processing system : DH-CG400 High resolution image capture card
Six The data processor graphics data processing and signal generation cross line
Seven Micro image measuring computer operating system ( Software B)