- 如果您对该产品感兴趣的话,可以
- 产品名称:MP526 conductivity / dissolved oxygen measuring instrument
- 产品型号: MP526
- 产品展商:Shanghai Sanxin instrumentation
- 产品文档:无相关文档
简单介绍
The laboratory for high precision measurement of conductivity and dissolved oxygen. Suitable for biotechnology, aquaculture, power plants and environmental protection industries.
产品描述
| Conforming to international normsGLPRequirements include automatic calibration, automatic temperature compensation and data storage, RS232Intelligent functions such as output, clock display, function setting and self diagnostic information. |
| There are three different measurement patterns:Steady display mode; timing measurement mode; continuous measurement mode. |
| Automatic recognition8There are two series of standard solutions for the conductivity standard solution:Europe and America series and Chinese series. |
| Advanced conductivity measurement techniques are used with constantK=1Conductive electrode Just a little calibration, you can meet0.5 S/cm mS/cmMeasurement accuracy requirements. ~ 200 |
| - Switchable conductivity, TDSSalinity and resistivity.TDSAnd salinity are calculated by polynomial to ensure the conversion precision of full range. |
| The model of conductivity measurement has the function of high pure water nonlinear temperature compensation. |
| The measurement mode of dissolved oxygen has the function of automatic temperature compensation, automatic salinity compensation and automatic air pressure compensation. |
| The polarographic dissolved oxygen electrode with a new structure can measure temperature, salinity and dissolved oxygen simultaneously. The electrode is calibrated with a special dissolved oxygen electrode, and the electrode polarization is only required3~5 min. |
| The instrument has a unique product serial number. |
|
- accord withIP54Dust prevention and splash grade, instrument socket with silicone cap seal protection.
|
|
Conductivity
|
Measuring range
?
?
?
?
?
Resolving power
Accuracy
Temperature compensation range
Electrode constant
Reference temperature
|
Conductivity: (0.00~20.00) S/cm (20.0~200.0) S/cm
(200~2000) S/cm (2.00~20.00) mS/cm
(20.0~200.0) mS/cm (200~2000) mS/cm (K=10)
Resistivity: (0 ~ 100) M cm.
TDS: (0 ~ 100) g/L
Salinity: (0 ~ 100) ppt
0.01/0.1/1 S/cm 0.01/0.1/1 mS/cm
Electric meter: FSMatching: 0.80%FS + + 0.5%
(0 ~ 50) C (automatic)
0.1 / 0.5 / 1 / 5 / 10 / 50 / 100 cm-1
25 DEG, 20 DEG and18 DEG
|
|
Dissolved oxygen
|
Measuring range
Resolving power
Accuracy
Response time
Residual current
Temperature compensation range
SalinityCompensation range
PressureCompensation range
Automaticcalibration
Electrode type
|
(0 ~ 20) mg/L (PPM) (0 ~ 200)%
0.1/0.01 mg/L (PPM) 1/0.1%
Electric meter: mg/LMatching: mg/L + 0.40 + 0.10
Less than 30 s (at 25 90%response)
Less than 0.1 mg/L
(0 ~ 45) C (automatic)
(0 ~ 45) PPT (automatic)
(80 ~ 105) kPa (automatic)
Be full of waterandAir saturated with airandThe water;
Polarographic
|
|
Temperature
|
Measuring range
Resolving power
Accuracy
|
-10 ~ 110 DEG C
0.1 C
5~ 60 C Range: + 0.4 + - 0.8 DEG C RestRange
|
|
Other technical parameters
|
Data storage
Storage content
Power Supply
Communication interface
Sizeandweight
QualityandSecurity authentication
|
600group
Numbering of measurement, measured value, temperaturevalue, ATCorMTCstate, Measurement date, Measurement time
DC9V/300mA
RS232
160 * 190 * 70mm/880g
ISO9001:2000, CEandCMC
|
|
Working conditions
|
Environmental Sciencetemperature
Environmental Sciencehumidity
IPGrade
|
10 ~ 30 DEG C
Less than or equal to 80%
IP54 Dust prevention and splash prevention
|